Panic Hardware for Single-Leaf Doors with 1-Point Locking PHA 1102 DORMAKABA PHA 1102 panic hardware for single-leaf escape doors with single-point horizontal locking. The door opens quickly by pushing the panic bar even when locked from outside. For door leaves up to 1100 mm wide.

Designed for emergency exits and escape routes in public and commercial buildings.

Key benefits

  • single-point horizontal locking
  • fast opening by pushing the panic bar
  • for left- and right-handed doors
  • surface-mounted installation
  • for emergency exits and escape routes
  • tested for fire and smoke doors
  • EN 1125 certified; supplier also specifies EN 1634

Set contents

  • DORMAKABA PHA 1102 F – single-point panic mechanism
  • 1130 mm panic bar

External hardware such as DORMAKABA PHT 10 is selected separately.

Technical specifications

  • Product type: surface-mounted panic hardware
  • Model: DORMAKABA PHA 1102
  • Designation: D1/1B
  • Locking type: single-point horizontal
  • Application: single-leaf doors
  • Maximum door leaf width: 1100 mm
  • Maximum door leaf height: 2270 mm
  • Door leaf thickness: 40–50 mm
  • Maximum door leaf weight: 250 kg
  • Panic bar length: 1130 mm
  • Installation: surface-mounted
  • Door handing: left and right
  • Finish: matt silver
  • Certification: EN 1125, EN 1634
  • EAN: 8584138449358

Application

Designed for emergency exits and escape routes in public and commercial buildings.

Installation and maintenance

The device is surface mounted. The horizontal panic bar is normally installed approximately 900 to 1100 mm above finished floor level. Operation and fixing points should be inspected regularly.

Frequently asked questions

Which doors is PHA 1102 intended for?

Single-leaf emergency exit doors.

Can it be used on left- and right-handed doors?

Yes.

What is the maximum door width?

1100 mm.

Is it suitable for fire doors?

Yes, subject to compatibility with the approved door assembly.